Skip to content
EPCMap

How energy efficient are homes in CW12 (Congleton, Cheshire East)?

Summary

Average rating

C70

Cheshire East average: D 67

Homes in CW12 have an average EPC rating of C (70), a little above the Cheshire East average of D (67).

Rated D or worse
44%
Cheshire East: 50%
Typical yearly energy cost
£901
EPCs since 2021, at prices then
Built before 1930
14%

How ratings are spread

Share of homes in each band, with the score range for each. The dark line marks the Cheshire East average.

  • Band A, score 92 to 100: 3% of homes; Cheshire East 1%.
  • Band B, score 81 to 91: 28% of homes; Cheshire East 18%.
  • Band C, score 69 to 80: 25% of homes; Cheshire East 30%.
  • Band D, score 55 to 68: 34% of homes; Cheshire East 36%.
  • Band E, score 39 to 54: 8% of homes; Cheshire East 11%.
  • Band F, score 21 to 38: 2% of homes; Cheshire East 2%.
  • Band G, score 1 to 20: <1% of homes; Cheshire East <1%.

Based on the latest energy performance certificate (EPC) for each of 12,858 homes, up to October 2026. EPCs rate homes from A (most efficient) to G (least), with a score out of 100.

What homes here are like

What EPC assessors recorded when they visited homes in CW12.

Main heating

Gas boiler86%
Oil boiler6%
Electric storage heaters2%
Heat pump2%
Other electric heating2%
Communal or district heating2%

Type of home

House78%
Flat11%
Bungalow11%
Maisonette1%

Walls, roof and windows

Solid walls, not insulated11%
Cavity walls, not insulated13%
Cavity walls, insulated43%
Solid walls, insulated1%
Other walls (timber, system-built or modern)32%
Loft insulation under 100 mm (homes with a loft)17%
Double or triple glazing throughout92%
Solar panels1%

Upgrades recommended for homes in CW12

Upgrades that are unusually common here come first, then the ones that appear most often on local EPCs. Costs are the EPC's guide prices, not quotes.

  • Solar panels (PV)

    On 81% of EPCs here (England and Wales: 66%).

    Typical cost: £5,000–£8,000
  • Solar water heating

    On 67% of EPCs here (England and Wales: 56%).

    Typical cost: £4,000–£6,000
  • Floor insulation

    On 46% of EPCs here (England and Wales: 49%).

    Typical cost: £4,000–£6,000
  • New condensing boiler

    On 18% of EPCs here (England and Wales: 20%).

    Typical cost: £2,200–£3,000
  • Cavity wall insulation

    On 15% of EPCs here (England and Wales: 16%). 13% of homes here have unfilled cavity walls.

    Typical cost: £500–£1,500
  • Heating controls

    On 15% of EPCs here (England and Wales: 16%).

    Typical cost: £350–£450

With all its recommended upgrades, 95% of homes here could reach a C rating or better.

On EPCs issued since 2021, making every recommended upgrade would cut the typical home's energy cost by about £85 a year, at the prices used when each EPC was issued.

Map of CW12 and nearby areas

How CW12 compares with the postcode districts around it.

WA16, Knutsford: D 64SK9, Wilmslow: D 67SK23, High Peak: D 66SK10, Macclesfield: D 67CW9, Northwich: D 67CW4, Crewe: D 68CW10, Middlewich: D 67SK11, Macclesfield: D 66CW7, Winsford: C 70SK17, Buxton: D 64CW11, Sandbach: C 70ST8, Stoke-On-Trent: D 63CW1, Crewe: C 69ST13, Leek: D 62CW2, Crewe: D 68ST6, Stoke-On-Trent: D 66ST7, Stoke-On-Trent: D 66ST1, Stoke-On-Trent: D 67ST9, Stoke-On-Trent: D 61ST2, Stoke-On-Trent: D 66CW5, Nantwich: D 68ST5, Newcastle: D 67ST10, Stoke-On-Trent: D 62CW4CW10SK11CW11ST8CW1CW2ST6ST7ST9CW12CW4CW10SK11CW11ST8CW1CW2ST6ST7ST9CW12
Colour shows each district's average rating. Tap a district to open it. CW12 Not enough EPCs

Neighbouring districts

Common questions

What holds energy ratings back in CW12?

Older homes, uninsulated walls and lofts, and electric or oil heating all pull ratings down.

Can I see the rating for my own home?

Yes. Individual certificates are on the official EPC Register on GOV.UK. EPCMap only shows figures for whole areas.

Are there grants for upgrades?

Some upgrades may qualify for government schemes, such as the Boiler Upgrade Scheme for heat pumps. Check current eligibility on GOV.UK.

How up to date is this?

We use the latest certificate for each home and refresh the data monthly. A certificate describes a home on the day it was assessed, so later improvements won't show until a new EPC is done.